| AC input voltage range |
85~264VAC; 120~370VDC |
| AC inrush current (max.) |
Cold start, 50A at 230VAC |
| DC adjustment range |
±10% by potentiometer |
| Overload protection Range |
110%~150% |
| Overload protection Type |
Hiccup mode, auto-recovery |
| Over voltage protection Range |
115%~135% rated output voltage |
| Over voltage protection Type |
Shut down o/p voltage, re-power on to recover |
| Withstand voltage |
3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 1.25kVAC, 1 minute |
| Working temperature |
-30~+70°C (refer to output derating curve) |
| Safety standards |
UL60950-1, IEC/EN60950-1, IEC/EN61558-1, EN61558-2-16, IEC/EN60335-1, CCC GB4943 approved |
| EMC standards |
EN55022 class B, EN55014, EN61000-3-2, 3, EN61000-4,2,3,4,5,6,8,11, GB9254 |
| Connection |
7P/9.5mm pitch terminal block |
| Dimension (LxWxH) |
129x 97x 30 |
There are no reviews yet.