Specification
AC input voltage range |
85~264VAC, 120~370VDC |
AC inrush current |
Cold start, 65A at 230VAC |
DC adjustment range |
±10% by potentiometer for single output; CH1 -5%~+10% by potentiometer for multiple output |
Overload protection |
>105%, hiccup mode |
Over voltage protection |
115%~135%, shut off |
Withstand voltage |
I/P – O/P: 3kVAC, I/P – FG: 1.5kVAC, O/P – FG: 0.5kVAC, 1 minute |
Working temperature |
-20~+70°C |
Vibration |
10~500Hz, 5G 10min. /1 cycle, period for 60 min. each along X, Y, Z axes |
Safety standards |
UL60950-1, TUV EN60950-1 approved |
EMC standards |
EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2) (35~150W) |
Connection |
Terminal block for input and output |
Dimension (LxWxH) |
62.5x 51x 28 |
Case No. |
971A |
Packing |
108pcs /15.0kg |
* Product Images are shown for illustrative purposes only and may differ from actual product.
There are no reviews yet.